Snow Load Calculator

This tool works a roof snow load through the ASCE 7 chapter 7 method. Enter your ground snow load along with the terrain and exposure, the thermal condition, the risk category and the roof slope, and it returns the flat roof load, the slope factor, the sloped roof load and the minimum load case, with the governing figure named. A second action computes the drift surcharge at a step between two roof levels, and a third converts a measured snow depth and density into pounds per square foot and total weight. The ground snow load is map data this site does not hold, so you supply it from your building department. The result is a load, not a structural check, and an engineer still has to sign off on the building that carries it.

Calculator Type
Measure In
Every figure you enter and every answer below follows this choice. The standard itself does not change: this is ASCE 7 either way, not the National Building Code of Canada and not Eurocode EN 1991-1-3.
How You Are Giving the Slope
Degrees is the usual way outside the United States, and it means the same thing in either unit system.
In psf, or in kPa, to match your choice above. From your building department or the ASCE Hazard Tool. This page cannot look it up.
Square feet, or square metres, to match your choice above. The horizontal area under the roof, not the area measured up the slope; snow loads act on the horizontal projection. 0 to skip it.
Widget
Measure In
Every figure you enter and every answer below follows this choice. The standard itself does not change: this is ASCE 7 either way, not the National Building Code of Canada and not Eurocode EN 1991-1-3.
In psf, or in kPa, to match your choice above. From your building department or the ASCE Hazard Tool. This page cannot look it up.
The fetch for the leeward drift, in feet. ASCE does not allow a fetch shorter than 25 ft.
The fetch for the windward drift, in feet. It is taken at three quarters of the leeward height.
Widget
Measure In
Every figure you enter and every answer below follows this choice. The standard itself does not change: this is ASCE 7 either way, not the National Building Code of Canada and not Eurocode EN 1991-1-3.
Pounds per cubic foot. Used only when you pick the last option above. Weigh a cut column of snow if you want this right. Blank means 12 pcf.
Square feet, or square metres. 0 to skip it.
In psf, or in kPa, to match your choice above. If you know what the roof was designed for, this compares today against it. 0 to skip it.